ETCR2000Clamp Ground Resistance Tester

Other name:Clamp Ground Resistance Tester

Specification Certificate of identification Service promise

Current limiting protection Power amplifier protection Voltage short circuit protection Open circuit protection Thermal protection of power amplifier

Note:Regarding product purchase, technical maintenance and other services, welcome to send email:

IntroductionParametersAccessoriesService

Application:

ETCR2000 clamp ground resistance tester is a major technological breakthrough in traditional grounding resistance measurement. It is widely used in the grounding resistance measurement of electric power telecommunications meteorology oilfield construction and industrial and electrical equipment. When measuring circuit grounding system it is not necessary to disconnect the each connection wire and use auxiliary electrode it is safe and quick easy to use. Can measure the grounding fault which can not be measured by the traditional method because this instrument measure the integrated value of grounding resistance and ground lead resistance apply to the occasion that can not use the traditional method.


Features:

Apply to all kinds of ground lead.(round bar flat bar angle iron).

Non-contact measured grounding resistance safe fast.

Without using assistant ground rod. Without interrupting the grounding of the device under test.

With double protecting insulation.

With strong anti-interference ability and high accuracy.

Use 5# alkaline batteries convenient for users.

Specification:

Power Supply

6VDC(4pcs 5#alkaline battery)

Working Temperature

-10~55

Relative Humidity

10%~90%

Size of Clamp

Square clamp: length 293mm width 90mm thickness 66mm

Jaw Opening Size

Square jaw: 28mm;

round jaw; 32mm

Weight (include battery)

Square jaw 1320g; round jaw 1120g

Measurement Range Conversion

Auto

External Magnetic Field

<40A/m

External Electric Field

<1V/m

Single Measurement Time

1 second

Measurement Frequency

>1kHz

Max Measurement Resolution

0.001Ω

Measurement Range

0.01~1000Ω

Current Measurement Range

0.00~30.0A

Tested Current Frequency

45~65Hz

Storage Capacity

50 groups

 Setting Range of Critical Value Resistance Alarm

1~199Ω

Setting Range of Critical Value Current Alarm

1~499mA


Quality Keep Improving - Service Pursuing Perfection Pre-sales service commitment Provide professional consulting service; dedicated salesman and professional technical engineer to answer customer questions Ensure customer get the detailed information about the product in hand Reasonable price. Quotation stamped and confirmed by Manager

Welcome customers visit on-purchase service commitment The contract and the technical agreement to sign by both parties Being trustworthy, follow the requirements and ensure successful implementation of signed contracts and technical agreements Focus on communication, actively communicate with users, take notes of user’s questions and schedule, provide the necessary technical support. Move quick and efficient, professional on delivery, installation, debugging, training and others

After-sales service commitment Professional after-sales service department; ask and listen to customer’s feedback about the products and take records. Product guaranty: one year free warranty, life long maintenance, since the delivery of the product Provide solutions within 24 hours when there is problems feedback from customer. Professional research and development team.

Recommended products

Email:
whgdmk@yeah.net
Skype:
Emma Lei
live:.cid.d703d549beaabb3e
电话:
+8618164248846