400-627-1108Mobile station
|Chinese|English

Product

Current Position:Home > Product > Power Energy Analyzer

Product details

HGQA-C Verification device of transformer with high speed multipole

Other name:Verification device of transformer with high speed multipole station

Specification Certificate of identification Service promise

Current limiting protection Power amplifier protection Voltage short circuit protection Open circuit protection Thermal protection of power amplifier

Note:Regarding product purchase, technical maintenance and other services, welcome to send email:

IntroductionParametersAccessoriesService
High-speed transformer verification device is a new generation of transformer verification device developed by our company. The design idea of virtual instrument is adopted. The user only needs to operate the virtual instrument interface on the computer screen through the mouse and keyboard to input the transformer type range accuracy level capacity power factor and other parameters can complete automatic testing of current transformers and voltage transformers as well as analysis calculation and database management of test results and can be printed according to user needs various records and certificates. 



1. The automatic mutual-inductor calibration platform adopts a single chip microcomputer to realize the functions of measurement control and display.
 
2. With computer interface improve the level of office automation and reduce the labor intensity.
 
3. Can have a large screen display provide a friendly operation interface and rich measurement information.
 
4. It can automatically realize the measurement of the transformer and can automatically switch the current and voltage load box.
 
5. Possess good catching measures and be able to promptly inform users of wrong information.
 
6. This automatic transformer calibration station can reach level 2.
 
7. The transformation ratio of the standard transformer and the tested transformer does not have to be equal as long as the rated primary voltage or rated primary current of the standard transformer is greater than or equal to the rated value of the tested transformer it can be directly verified which is more convenient to use.

 
1. Environmental conditions
 
1) Temperature: 5 ℃ ~ 40 ℃
 
2) Relative humidity: <80% (25 ℃)
 
3) Altitude: <2500m
 
4) Power frequency: 50Hz ± 0.5Hz
 
5) Power supply voltage: 220V ± 5V
 
2. Measuring range
 
1) In-phase component (%): 0.0001 ~ 200.0 Resolution: 0.0001
 
2) Orthogonal component (minutes): 0.001 ~ 999.9 Resolution: 0.001
 
3) Impedance (W): 0.0001 ~ 60.0 Resolution: 0.0001
 
4) Admittance (ms): 0.0001 ~ 60.0 Resolution: 0.0001
 
3. Basic error
 
1) In-phase component: DX = ± (X × 2% + Y × 2% ± 2 words)
 
2) Quadrature component: DY = ± (X × 2% + Y × 2% ± 5 characters)
 
"X" "Y"-display value of the instrument
 
"5 words"-quantization error of the instrument
 
3) Dial indicator: level 1
 
4. Working range
 
1) Current: (1% -149%) In (In = 5A); (5% -149%) In (In = 1A)
 
5. Workload:
 
1) Current: To vs Tx <0.12Wcosj = 1
 
6. Polarity error indication
 
1) When the error is over 5% of the rated working current and the error exceeds 180% there should be a polarity indication.
 
     Note: If it is more than 10% of the rated operating current the polarity indication should not appear indicating that the software is faulty please do not increase the current so as not to burn the instrument.
 
7. Variable ratio error indication
 
1) When the rated working current is more than 5% and the error exceeds 30% but less than 180% there should be a ratio error indication.
 
8. Insulation and withstand voltage test and description
 
1) Terminal Tx and ground terminal communicate
 
2) Both the K and D terminals are disconnected from the ground terminal
 
3) The power socket can withstand 1.5kV and 1min withstand voltage to the shell

Quality Keep Improving - Service Pursuing Perfection Pre-sales service commitment Provide professional consulting service; dedicated salesman and professional technical engineer to answer customer questions Ensure customer get the detailed information about the product in hand Reasonable price. Quotation stamped and confirmed by Manager

Welcome customers visit on-purchase service commitment The contract and the technical agreement to sign by both parties Being trustworthy, follow the requirements and ensure successful implementation of signed contracts and technical agreements Focus on communication, actively communicate with users, take notes of user’s questions and schedule, provide the necessary technical support. Move quick and efficient, professional on delivery, installation, debugging, training and others

After-sales service commitment Professional after-sales service department; ask and listen to customer’s feedback about the products and take records. Product guaranty: one year free warranty, life long maintenance, since the delivery of the product Provide solutions within 24 hours when there is problems feedback from customer. Professional research and development team.

Recommended products

Email:
whgdmk@yeah.net
Skype:
Emma Lei
live:.cid.d703d549beaabb3e
电话:
+8618164248846